Commercial – Ingleside, IL

Approx. 1600 sq. ft. commercial office suites

Boiler:  NTI Trinity 60,000

Insulation:  2” Ridgid foam Crete-Heat

System:  Four (4) zones with Honeywell controller and slab sensing thermostats, Caleffi 8 loop manifold with motorized valve actuators controlling individual loops

System designed with outdoor reset and warm weather shutdown and zone synchronization to maximize efficiency.